Cdi-torque MULTITEST Government User Manual Page 36

  • Download
  • Add to my manuals
  • Print
  • Page
    / 96
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 35
3-6
Setup and Programming
Setting Up High and Low Limits Alert
Torque/Force Mode
Use SET HIGH and SET LOW to protect the tool under test or
serve as a fastener installation torque or force preset alert. The
2000-610-02 produces a constant audible limits alert tone when
the input torque/force exceeds the SET LOW limit. It then
produces a pulsating limits alert tone when the input
torque/force exceeds the SET HIGH limit.
It is important to program these limits if statistical
analysis is to draw a histogram which includes
reporting out-of-limit parameters.
Changing transducers does not automatically change
SET HIGH and SET LOW limits.
Angle Mode
In the ANGLE mode, use SET LOW to program a clamping
torque limit and use SET HIGH to program an angle
measurement. For additional information refer to Torque-Angle
Measurement Modes in this chapter.
Setting Low Torque/Force Limit
1. Press SET LOW.
The LED display reads:
last SET LOW value , with one digit flashing
The LCD display reads:
Edit low limit - upper line
[units] - lower line
Change units of measure by pushing UNITS.
2. Select an LED digit to change (flashing) by pushing left
or right DIGIT.
3. Increment or decrement the selected digit by pushing up
or down VALUE. Push and hold up or down VALUE to
change the display quickly.
A decimal point "." appears between "9" and "0"
numerals. Maximum resolution is selected
automatically, regardless of decimal point position,
upon pushing ENTER. The program value is
absolute, for both ± readings.
4. Select and change the next LED digit using left and right
DIGIT and up and down VALUE. Continue until all digits
are set.
5. Press ENTER to return to measurements mode.
Page view 35
1 2 ... 31 32 33 34 35 36 37 38 39 40 41 ... 95 96

Comments to this Manuals

No comments