2-13
Functional Description and Specificatons
Torque/Force Transducers
Accuracy
±0.2% of reading @ 25°C, within specified range, when used as
prescribed with the 2000-610-02 Loader.
Range and Resolution
Refer to transducer-indicator range and display resolution tables
in Functional Description of this chapter.
Temperature
Operating Temperature
10 to 32°C (50 to 90°F)
Storage
-20 to 50°C (-2 to 122°F)
Humidity
Up to 90% non-condensing
Temperature Drift
+0.02%/°C (+.011%/°F)
MULTITEST Manual Loader Specifications
Input Torque (Hand Crank)
8 ft lb maximum
Output Torque
2000 ft lb ±20 degrees rotation maximum
Power Requirements (Safety solenoids)
115/230VAC ±10%, @ 50-60 Hz
Physical Dimensions
Width
45"
Height
50"
Depth
24"
Weight (including 2000-100-02 roll cab)
1500 lbs
Optional Calibration Fixturing (Load bars and weights)
±0.05% accuracy