Page view 26
2-11
Functional Description and Specifications
Specifications
MULTITEST Torque Calibration System
System Accuracy
±0.25% of reading @ 25°C
(Indicator and transducer calibrated together)
MULTITEST Transducers used with, but not calibrated
to, another MULTITEST Indicator provide a system
accuracy of ±0.5% of reading @ 25°C.
Temperature Drift
+0.03%/°C (+0.017%/°F)
Angle Precision
Bi-directional rotary encoder pulses/revolution X4
2000-610-02 Indicator
Display Accuracy
±0.05% of reading @ 25°C
Temperature
Operating Temperature
10 to 32°C (50 to 90°F)
Storage
-20 to 50°C (-2 to 122°F)
Humidity
Up to 90%, Non-condensing
Temperature Drift
+0.011%/°C, (+0.006%/°F)
Dimensions
Width 16.5"
Height 6.25"
Depth* 14.5"
*Includes handle, feet, printer and connectors
Weight
13.5 lbs
Power Supply
UL approved, 120VAC/220VAC, 50-60 Hz
Amperage, 3.15 amps